Uploaded image for project: 'PROFINET IO-Device V4'
  1. PROFINET IO-Device V4
  2. PSPNSV4-119

RCX_GET_DPM_IO_INFO_REQ not working as expected when using database configuration

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Major
    • Resolution: Fixed
    • Affects Version/s: V3.6.4.0
    • Fix Version/s: V3.6.6.0
    • Labels:
      None
    • Sprint:
      PI Sprint KW 31/32 2014
    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      the generic service RCX_GET_DPM_IO_INFO_REQ works fine when using PNS_IF_SET_CONFIGURATION_REQ.
      It does not work (returns either packet without any block or block with length info 5760) when using Sycon.net configuration with 1 byte input and 1 byte output data length.