Firmware crash or malfunctioning when handling multiple services related to remanent data in a short time

    Details

    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      When netX52 firmware is configured with database file and the ART certification testcase DCP_Access is executed the firmware is afterwards no longer working as expected. The problem is not limited to netX52 firmwares might affect other firmwares as well.

      It does not respond to requests on the network and the LEDs do not work as expected (no blinking and sometimes SYS LED is yellow).

      Issue may occur even when using configuration via mailbox but harder to reproduce.

      Only PNS V.4.8.0 is affected, Release branch PNS V4.4.0.x and all related Hotfix firmwares are not affected.