Details
-
Type: Bug
-
Status: Closed
-
Priority: Minor
-
Resolution: Fixed
-
Affects Version/s: V4.4.4.0
-
Fix Version/s: V4.4.7.0
-
Labels:None
-
Account:SPC Profinet Slave (SPCPROFINE)
Description
Unexpected (wrong) values are returned by HIL_GET_TRIGGER_TYPE_REQ in the following scenario.
- first HIL_SET_TRIGGER_TYPE_REQ with invalid parameters is sent to firmware
- the request is rejected (as expected) with invalid parameter
- second HIL_GET_TRIGGER_TYPE_REQ is sent to firmware
- the confirmation returns a mixture between expected values and the rejected values from previous HIL_SET_TRIGGER_TYPE_REQ
Attachments
Issue Links
- is blocked by
-
PSPNSV4-1017 Upgrade Generic AP Task to V1.0.0.1
- Closed
- mentioned in
-