      Description

      When a legacy AR connection is established and the controller parameterizes fast startup, the Parameter Speedup Supported service (PNS_IF_PARAMET_SPEEDUP_SUPPORTED_IND command) might not be generated by the firmware.

      It is expected that the indication is generated in this usecase.