Uploaded image for project: 'PROFINET IO-Device'
  1. PROFINET IO-Device
  2. PSPNS-2948

Invalid coding of PDInterfaceMrpDataAdjust (V1.1) and PDInterfaceMrpDataCheck (V1.1) (certification issue)

    Details

    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      The encoding of PDInterfaceMrpDataAdjust (V1.1) and PDInterfaceMrpDataCheck (V1.1) is invalid. When reading MRP data records, it is expected that the configured MRP parameters are sent in correct coding according to the same structure version as they are written by the IO controller.