DCP Set frames with Start or Stop TransactionBlock are not handled correctly

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V3.14.0.0
    • Fix Version/s: V3.14.0.13
    • Component/s: None
    • Labels:
    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      If a DCP Set frame contains a Start TransactionBlock or StopTransaction block, these blocks are currently negatively answered. However, it is expected that these optional blocks are handled correctly and are not answered negatively.