Uploaded image for project: 'PROFINET IO-Device'
  1. PROFINET IO-Device
  2. PSPNS-2940

inconsistent link state in case of instable link

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V3.14.0.0
    • Fix Version/s: V3.14.0.12, V3.14.1.0
    • Component/s: None
    • Labels:
      None

      Description

      If the link is instable and changes between "up" and "down", this may result in a situation that some parts of the software stay in state "link down" although final link state is "link up". In case of error, the device may not send LLDP frames although a physical link exists.

       

      It seems that only components using  Drv_EddRegisterLinkStatus() are affected.

      This issue was only observed on netX51 FiberOptic hardware. In theory it could occur on other platforms and for regular Ethernet as well, but chances are very low.

        Attachments

          Expenses

            Activity

              Status Description

                People

                • Reporter:
                  BMeyer Benjamin Meyer
                • Votes:
                  0 Vote for this issue
                  Watchers:
                  0 Start watching this issue

                  Dates

                  • Created:
                    Updated:
                    Resolved: