Uploaded image for project: 'PROFINET IO-Device'
  1. PROFINET IO-Device
  2. PSPNS-2938

Invalid initial value of DCERPC serial number

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V3.14.0.0
    • Fix Version/s: V3.14.0.11, V3.14.1.0
    • Component/s: None
    • Labels:

      Description

      The ApplicationReady sent by IO Device uses an unexpected DCERPC SerialNumber of 1. It is expected to be 0 as defined by the DCERPC specification.

      This issue can be detected in manual inspection of Profinet certification.