unexpected NameOfStation used when combining database configuration and PNS_IF_RESET_FACTORY_REQ

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: None
    • Fix Version/s: V3.14.0.8, V3.14.1.0
    • Component/s: None
    • Labels:
      None

      Description

      When the undocumented service PNS_IF_RESET_FACTORY_REQ is used in combination with Sycon.net database configuration, unexpected NameOfStation may be used by the firmware.

      In case the same database is again downloaded after the specific service is used, the NameOfStation in the database will be used.

      However, after a power cycle, the NameOfStation will be empty again, even if nothing was changed. This is unexpected. After using the service and downloading a database, it is expected that the name inside the database is used.