Uploaded image for project: 'PROFINET IO-Device'
  1. PROFINET IO-Device
  2. PSPNS-2919

Mismatch between Interface and LLDP Mib for single port devices

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V3.4.36.1, V3.11.0.0
    • Fix Version/s: V3.14.0.6, V3.14.1.0
    • Component/s: None
    • Labels:
      None

      Description

      When the protocolstack is configured for single port mode, the Mib-Database returns different values for lldpLocPortDescr and ifDescr. (via SNMP)

      According to LLDP-MIB, values used in the lldpLocPortDescr shall be contained in ifTable's field ifDescr.