Uploaded image for project: 'PROFINET IO-Device'
  1. PROFINET IO-Device
  2. PSPNS-2859

when using service PNS_IF_GET_PARAMETER_REQ its parameter ulAPI is not evaluated correctly (for some subtypes)

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V3.13.2.0
    • Fix Version/s: V3.13.3.0, V3.14.0.0
    • Component/s: None
    • Labels:
      None
    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      The service PNS_IF_GET_PARAMETER_REQ offers the possibility to read out several parameters from the Profinet IO Device stack. The parameter is defined by the request packet field "ulParameterType". In addition the dedicated submodule is addressed by parameters ulApi, usSlot and usSubslot.

      For some parameter types the content of ulAPI is not evaluated correctly.

      A check for "ulAPI" shall be added for the following subtypes:

      • PNS_IF_PARAM_ETHERNET  (ulAPI == 0 required)
      • PNS_IF_PARAM_PORT_STATISTIC (ulAPI == 0 required)

        Attachments

          Expenses

            Activity

              Status Description

                People

                • Reporter:
                  BMeyer Benjamin Meyer
                • Votes:
                  0 Vote for this issue
                  Watchers:
                  0 Start watching this issue

                  Dates

                  • Created:
                    Updated:
                    Resolved: