Modify handling of PNS_IF_CONNECT_REQ_DONE_IND and its response

    Details

    • Type: Change
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: None
    • Fix Version/s: V3.13.2.0, V3.14.0.0
    • Component/s: None
    • Labels:
      None
    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      The service PNS_IF_CONNECT_REQ_DONE_IND is generated by protocol stack after it has finished the comparison of the expected and the plugged submodules. Thus no more PNS_IF_CHECK_IND will be generated.

      Currently the protocol stack send ConnectResponse on the network to the IO Controller without user interaction after PNS_IF_CONNECT_REQ_DONE_IND has been sent.

      The behavior shall be modified in the following way:

      • ConnectResponse is not sent to IO Controller after generation of PNS_IF_CONNECT_REQ_DONE_IND
      • after receipt of PNS_IF_CONNECT_REQ_DONE_RES the stack shall generate the ConnectResponse to IO Controller
      • PNS_IF_CONNECT_REQ_DONE_IND shall be added to the list of services for which AP task supervises the reaction of application. In case of no response in configured timeout the AP task shall generate a response to the protocol stack which aborts the connection establishment with an error code. In addition a PNS_IF_USER_ERROR_IND needs to be generated.

       