Uploaded image for project: 'PROFINET IO-Device'
  1. PROFINET IO-Device
  2. PSPNS-2828

PNS_IF_SET_OEM_PARAMETER_REQ with ParameterType 9 (set I&M5 data) is rejected if used prior to PNS_IF_SET_CONFIGURATION_REQ

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V3.12.0.0
    • Fix Version/s: V3.13.0.3, V3.13.2.0, V3.14.0.0
    • Component/s: None
    • Labels:
      None
    • Sprint:
      aktuelle Aufgaben
    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      It is expected that the ParameterType 9 can be set by application even if the stack is unconfigured. Otherwise this specific ParameterType behaves different to the other existing ParameterTypes which enforce their usage prior setting the configuration.

        Attachments

          Expenses

            Activity

              Status Description

                People

                • Reporter:
                  BMeyer Benjamin Meyer
                • Votes:
                  0 Vote for this issue
                  Watchers:
                  0 Start watching this issue

                  Dates

                  • Created:
                    Updated:
                    Resolved: