WhIle testing IRT in large topologies instability and unexpected non-established connections can be observed.
In error case the IO Device reports an unexpected diagnosis (e.g. PTCP mismatch, PeerChassisID mismatch, ...).
In error case the RTC3PSM state of the IO Device reported to the neighbor via LLDP may be wrong (UP) altough internal RTC3PSM state is RUN (which is reported via SNMP or Profinet records).
The detailed circumstances under which the issue occurs is not yet clear. Especially in networks with more than 32 netX devices the issue can be observed.
This ticket is a followup of PSPNS-2801. It was observed that the fix does not fix all issues observed with current development branch.
However all public available versions of PNS v3.13.0.x will be fixed with PSPNS-2801.
Attachments
Issue Links
- discovered by
-
PSPNS-2801 [netX51]: IRT communication may be instable or not even possible to be established in large networks
- Closed
- is blocked by
-
PSPNS-2853 update to new PnD Switch and HAL V2.5.0.0
- Closed
- relates to
-
PSPNS-2656 update to PnD switch and HAL V2.3.0.0
- Closed