Uploaded image for project: 'PROFINET IO-Device'
  1. PROFINET IO-Device
  2. PSPNS-2794

Sometimes wrong management address reported by LLDP if remanent set

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V3.12.0.0
    • Fix Version/s: V3.12.4.0, V3.13.0.0
    • Component/s: None
    • Labels:
      None
    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      When the IP address is stored permanently a wrong management address in LLDP Frame and LLDB MIB might be reported after a powercycle.

      It is expected that a proper management address is reported after a powercycle.

      This issue could only be reproduced by applications that set "Bus State off" on startup prior setting any configuration to the firmware although firmware reports "bus off".

        Attachments

          Issue Links

            Expenses

              Activity

                Status Description

                  People

                  • Reporter:
                    AMesser Andreas Messer
                  • Votes:
                    0 Vote for this issue
                    Watchers:
                    0 Start watching this issue

                    Dates

                    • Created:
                      Updated:
                      Resolved: