Uploaded image for project: 'PROFINET IO-Device'
  1. PROFINET IO-Device
  2. PSPNS-2786

[loadable module]: change default Phy configuration timeout to 2 minutes

    Details

    • Type: Change
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: None
    • Fix Version/s: V3.12.3.0, V3.13.0.0
    • Component/s: None
    • Labels:
      None
    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      Currently loadable module will enable all PHYs in "Autonegotiation mode" 60 seconds after its start if

      • no remanent data exists in flash
      • no configuration from host is given

      Applications storing the remanent data themselves and running on an external host CPU may take longer than 60s to start until the remanent data is given to firmware.

      However in this case the PHYs have already been activated with default settings. These defaults may not respect remanent data which could have disables a port.

        Attachments

          Expenses

            Activity

              Status Description

                People

                • Reporter:
                  BMeyer Benjamin Meyer
                • Votes:
                  0 Vote for this issue
                  Watchers:
                  0 Start watching this issue

                  Dates

                  • Created:
                    Updated:
                    Resolved: