unexpected SF LED behavior after ChannelInit in case application generated diagnosis exists

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V3.7.0.0
    • Fix Version/s: V3.12.3.0, V3.13.0.0
    • Component/s: None
    • Labels:
      None
    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      If application generates a diagnosis at runtime and later uses the sequence

      • RCX_CONFIG_DELETE_REQ
      • RCX_CHANNEL_INIT_REQ

      to delete the protocol stack configuration the SF LED stays static ON indicating a diagnosis exists.

      Expected behavior: After given sequence no diagnosis shall exist in protocol stack and SF LED shall be off.