Uploaded image for project: 'PROFINET IO-Device'
  1. PROFINET IO-Device
  2. PSPNS-2761

DPM watchdog time is immediately modified when a SetConfiguration packet is received

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V3.12.0.0
    • Fix Version/s: V3.12.3.0, V3.13.0.0
    • Component/s: None
    • Labels:
      None
    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      In case the firmware is already configured and running a second SetConfiguration Request can be received at any point in time. However its configuration shall not be applied until a ChannelInit is requested.

      Current AP task implementation immediately uses the DPM watchdog timing from the received SetConfiguration Request without waiting for ChannelInit command.

        Attachments

          Expenses

            Activity

              Status Description

                People

                • Reporter:
                  BMeyer Benjamin Meyer
                • Votes:
                  0 Vote for this issue
                  Watchers:
                  0 Start watching this issue

                  Dates

                  • Created:
                    Updated:
                    Resolved: