Uploaded image for project: 'PROFINET IO-Device'
  1. PROFINET IO-Device
  2. PSPNS-2697

A read record of PE status contained in submodules not linked to an AR generates corrupted API numbers.

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V3.12.0.0
    • Fix Version/s: V3.12.0.9, V3.12.2.0, V3.13.0.0
    • Component/s: None
    • Labels:
      None
    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      An improved internal regresion test shows an issue in case PE entity list is read and submodules with PE entity without an ApplicationRelation exist. In addition the "Remove PE entity" service needs to be used upfront.

      In case of error invalid API is reported in record object.

        Attachments

          Expenses

            Activity

              Status Description

                People

                • Reporter:
                  ATilatti ATilatti (Inactive)
                • Votes:
                  0 Vote for this issue
                  Watchers:
                  0 Start watching this issue

                  Dates

                  • Created:
                    Updated: