Adjust default I&M5 behavior to be only active for specific targets by default

    Details

    • Type: Change
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: None
    • Fix Version/s: V3.12.2.0, V3.13.0.0
    • Component/s: None
    • Labels:
      None
    • Sprint:
      PI Sprint 2017 KW wrong, aktuelle Aufgaben
    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      In case the protocol stack handles I&M data it is expected that I&M5 dataset is delivered for some products. For other products I&M5 shall not be delivered.

      The implementation in firmware shall be changed in such a way that standard Hilscher CommunicationSolution products (cifX, comX, netJACK) have I&M5 activated by default without any user interaction. The same applies for all netRAPID targets.

      Other targets, especially NXLFW and NXLOM distributions shall not handle I&M5 automatically, instead requests shall be answered with "invalid index". This is a change in NXLFW behavior compared to previous firmware versions that supported I&M5 for NXLFW by default.