Uploaded image for project: 'PROFINET IO-Device'
  1. PROFINET IO-Device
  2. PSPNS-2659

Unexpected behavior when reading record index 0x80A1

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V3.12.0.0
    • Fix Version/s: V3.12.0.7, V3.12.2.0, V3.13.0.0
    • Component/s: None
    • Labels:
      None
    • Sprint:
      PI Sprint 2017 KW wrong
    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      According to current specification the record index 0x80A1 is reserved but the protocol stack seems to forwards it to the application. It is unclear why this is done and if it is necessary. Before the PE-ASE was implemented all PE-Energy records have been forwarded to the application. Before changing this behavior, existing PE-Energy implementations according to old standards have to be considered.

        Attachments

          Issue Links

            Expenses

              Activity

                Status Description

                  People

                  • Reporter:
                    AMesser Andreas Messer
                  • Votes:
                    0 Vote for this issue
                    Watchers:
                    0 Start watching this issue

                    Dates

                    • Created:
                      Updated:
                      Resolved: