Uploaded image for project: 'PROFINET IO-Device'
  1. PROFINET IO-Device
  2. PSPNS-2632

in case of application controlled startup LLDP frames are sent to early to network

    Details

    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      In case of application controlled startup it is expected behavior that LLDP frames are not sent to network until application allows network access (by setting Bus ON).

      Current implementation in protocol stack starts sending LLDP frames immediately after configuration is activated with ChannelInit (without respecting Bus state).

      This may be an issue during automated certification testcase PDEV_Check_OnePort (depending on some other timings).

        Attachments

          Expenses

            Activity

              Status Description

                People

                • Reporter:
                  BMeyer Benjamin Meyer
                • Votes:
                  0 Vote for this issue
                  Watchers:
                  0 Start watching this issue

                  Dates

                  • Created:
                    Updated:
                    Resolved: