Stack rejects device access write request

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V3.11.1.0
    • Fix Version/s: V3.11.4.0, V3.12.0.0
    • Component/s: Stack
    • Labels:
      None
    • Account:
      SPC Profinet Slave V5 operational (SPCPROFINE)

      Description

      Due to wrong owner relationship check the stack rejrcts all device access write requests.

      In principle, only interface and port-Submodule specific records must be rejected by stack, all other records e.g. I&M, manufacturer and profile specific records should be forwarded to the aplllication.