Uploaded image for project: 'PROFINET IO-Device'
  1. PROFINET IO-Device
  2. PSPNS-2563

[netX5]: HAL Edd function GetPortStatus does not provide full information (certification)

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V3.11.0.0, V3.11.0.4
    • Fix Version/s: V3.11.0.5, V3.11.1.0, V3.12.0.0
    • Component/s: netx 5
    • Labels:
      None
    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      The "bOperStatus" element is never set to any value.

      The result of this lack is:

      •  wrong content of the SNMP object ifOperStatus=0 (.iso.org.dod.internet.mgmt.mib-2.interfaces.ifTable.ifEntry.ifOperStatus or .1.3.6.1.2.1.2.2.1.8) but allowed are up ( 1 ) , down ( 2 ) , testing ( 3 )
      • wrong content of the SNMP object ifAdminStatus=down (2) on port without link but should be reported ifAdminStatus=up (1) - because it is the desired state of the interface (no any settings from PROFINET controller for ports was done).

        Attachments

          Expenses

            Activity

              Status Description

                People

                • Reporter:
                  Artem Artem R. [X] (Inactive)
                • Votes:
                  0 Vote for this issue
                  Watchers:
                  0 Start watching this issue

                  Dates

                  • Created:
                    Updated:
                    Resolved: