Details
-
Type: Bug
-
Status: Closed
-
Priority: Major
-
Resolution: Fixed
-
Affects Version/s: V3.10.0.0
-
Fix Version/s: V3.10.0.10, V3.11.0.0
-
Component/s: Stack
-
Labels:
-
Account:SPC Profinet Slave (SPCPROFINE)
Description
According to profinet specification, if the Device receives multiple alarm indications simultaneously the AR shall be aborted with Error "AR protocol violation" and may acknowledge the fist alarm indication. Currently, the IO Device sends immediately valid transport acknowledges (ACK-RTA) and alarm acknowledge (DATA-ACK) with wrong SendSeqNum and AckSeqNum to the fist received alarm. This Issue can be reproduced using ALPMR3 testcase of PNIO RT Tester.
Attachments
Issue Links
- discovered by
-
PSPNS-2437 allow certification according PNIO_Version 2.33 with October testbundle 2016
- Closed