Uploaded image for project: 'PROFINET IO-Device'
  1. PROFINET IO-Device
  2. PSPNS-2501

Peer PTCP mismatch diagnosis not supported

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V3.7.0.0
    • Fix Version/s: V3.11.0.0
    • Component/s: Stack
    • Labels:
      None
    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      According to PNIO Diagnosis Guideline if a device supports and accepts PortDataCheck record with valid CheckSyncDifference subblock the peer PTCP mismatch diagnosis shall be generate if in a SyncDomain either no valid or differents SyncMaster MAC Addresses detected, and since the stack supports CheckSyncDifference with CableSyncMode.SyncMaster = true this diagnosis shall also be supported.