Uploaded image for project: 'PROFINET IO-Device'
  1. PROFINET IO-Device
  2. PSPNS-2336

NXLFW delivery does not contain TCP/IP header files

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V3.9.0.0
    • Fix Version/s: V3.9.1.0, V3.10.0.0
    • Component/s: None
    • Labels:
      None
    • Sprint:
      PI Sprint KW 43 2015
    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      If host wants to use TCP/IP interface on DPM Channel 1 he needs the API and error headers of TCP/IP.
      Thus they shall be provided on NXLFW CD (folder network drive).

        Attachments

          Expenses

            Activity

              Status Description

                People

                • Reporter:
                  BMeyer Benjamin Meyer
                • Votes:
                  0 Vote for this issue
                  Watchers:
                  0 Start watching this issue

                  Dates

                  • Created:
                    Updated:
                    Resolved: