Uploaded image for project: 'PROFINET IO-Device'
  1. PROFINET IO-Device
  2. PSPNS-2321

None-fixed datatype TLR_BOOLEAN is used in in API Header

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Major
    • Resolution: Fixed
    • Affects Version/s: V3.8.0.0
    • Fix Version/s: V3.9.0.1, V3.9.1.0, V3.10.0.0
    • Component/s: None
    • Labels:
      None
    • Sprint:
      PI Sprint KW 38/39 2015
    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      The type TLR_BOOLEAN is defines as unsigned int. Therefore it is not portable and must not be used within the API Header of a Protocol Stack. It results in an invalid packet structure on the host side for 8, 16 or 64 bit host CPUs. The type TLR_BOOLEAN32 should be used instead.

        Attachments

          Issue Links

            Expenses

              Activity

                Status Description

                  People

                  • Reporter:
                    AMesser Andreas Messer
                  • Votes:
                    0 Vote for this issue
                    Watchers:
                    0 Start watching this issue

                    Dates

                    • Created:
                      Updated:
                      Resolved: