Uploaded image for project: 'PROFINET IO-Device'
  1. PROFINET IO-Device
  2. PSPNS-2282

if configured to only use 1 port for Profinet the stack shall not indicate to be MRP capable

    Details

    • Sprint:
      PI Sprint KW 27 2015
    • Account:
      SPC Profinet Slave (SPCPROFINE)
    • Story Points:
      3

      Description

      If the Profinet IO Device protocol stack is configured to only use 1 port for Profinet usage of MRP makes no sense and is not accepted by certification.

      Thus in this special scenario

      • MRP client shall never be activated
      • LLDP frame shall not contain the MRP-TLV
      • all MRP related records shall not be supported (answer with invalid index)
      • sumation records (e.g. PDPortDataReal, PDRealData) shall not contain MRP blocks

        Attachments