Profinet stack issues "store remanent data indication" again without waiting for previous confirmation

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V3.7.0.2, V3.7.2.0
    • Fix Version/s: V3.7.0.4, V3.7.3.0, V3.8.0.0
    • Component/s: Stack
    • Labels:
      None
    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      If environment frequently updates the data that should be stored permanently than the stack issues the "store remanent data indication" again and again to application or AP task without waiting for previous "store remanent data confirmation".
      This may lead to full queues.