Details
-
Type: Bug
-
Status: Closed
-
Priority: Minor
-
Resolution: Fixed
-
Affects Version/s: V3.7.0.0
-
Fix Version/s: V3.8.0.0
-
Component/s: None
-
Labels:
-
Sprint:PI Sprint KW 12 2015
-
Account:SPC Profinet Slave (SPCPROFINE)
Description
The current implementation to handle Read Request for index RecordOutputDataObjectElement (0x8029) is only working properly if the host application cyclically requests IO update.
If no IO update is requested by the hos (or it is only done very slow) this has unexpected negative impact to handling of this specific acyclic object which is unexpected.
This may lead to the situation that certification testcase IOPS_CHECK fails.
Attachments
Issue Links
- relates to
-
PSPNS-2204 Read index "RecordOutputDataObjectElement" delivers wrong values in "Output Data" on Implicit and DeviceAccess
- Closed