RTC3 FrameIDs are accepted for usage in RTC1 AR (certification issue)

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Major
    • Resolution: Fixed
    • Affects Version/s: V3.5.43.0
    • Fix Version/s: V3.5.53.0, V3.7.0.0
    • Component/s: None
    • Labels:
      None
    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      In case the IO Controller requests ARType IO Controller AR, thus IRT is not used, but in the IOCRBlock he requests usage of RTC3 FrameIDs (which are reserved for IRT) this Connect Request shall be rejected by the IO Device.
      Currently the Request is accepted and answered positively.

        Attachments

          Expenses

            Activity

              Status Description

                People

                • Reporter:
                  BMeyer Benjamin Meyer
                • Votes:
                  0 Vote for this issue
                  Watchers:
                  0 Start watching this issue

                  Dates

                  • Created:
                    Updated: