Uploaded image for project: 'PROFINET IO-Device'
  1. PROFINET IO-Device
  2. PSPNS-2060

DCP Set not possible after malformed DCP Set frame

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Critical
    • Resolution: Fixed
    • Affects Version/s: V3.5.50.0
    • Fix Version/s: V3.5.51.0
    • Component/s: Firmware
    • Labels:
      None
    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      Each DCP SET frame, which includes other options than the control option with reset suboption shall be deemed invalid. If the stack receive such frames, all dcp set requests are rejected with the same error (In operation, SET not possible).
      According to Profinet spec the options list of SET frame shall contain one request only, if a suboption is set to FactoryReset or ResetToFactory Setting. In this case each malformed frame shall be rejected with error (SET not possible).

        Attachments

          Expenses

            Activity

              Status Description

                People

                • Reporter:
                  BMeyer Benjamin Meyer
                • Votes:
                  0 Vote for this issue
                  Watchers:
                  0 Start watching this issue

                  Dates

                  • Created:
                    Updated:
                    Resolved: