Incorrect handling of Read Implicit Requests for AR-specific indexes (certification issue)

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Major
    • Resolution: Fixed
    • Affects Version/s: V3.5.43.0
    • Fix Version/s: V3.5.48.0
    • Component/s: None
    • Labels:
      None
    • Sprint:
      PI Sprint KW 38/39 2014
    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      If an AR-specific index (value range 0xE000 - 0xEFFF) is read using service "Read Implicit Record" and Target_ARUUID is set to NIL the record shall be rejected.
      The checking of block "IODReadReqCheck" is not implemented according to specification.

        Attachments

          Expenses

            Activity

              Status Description

                People

                • Reporter:
                  BMeyer Benjamin Meyer
                • Votes:
                  0 Vote for this issue
                  Watchers:
                  0 Start watching this issue

                  Dates

                  • Created:
                    Updated:
                    Resolved: