Uploaded image for project: 'PROFINET IO-Device'
  1. PROFINET IO-Device
  2. PSPNS-1655

wrong error code sent on dcp-request "reset to factory-settings" while aborting the AR (certification issue)

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Blocker
    • Resolution: Fixed
    • Affects Version/s: V3.5.20.0
    • Fix Version/s: V3.5.30.2, V3.5.31.0
    • Component/s: All Firmwares
    • Labels:
      None
    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      If a dcp-request "reset to factory-settings" is triggered the device shall send an alarm with error "dcp, reset to factory-settings" (0xcf, 0x81, 0xfd, 0x20), but it sends "dcp, station-name changed" (0xcf, 0x81, 0xfd, 0x1f)“.

      Certification testlab complains this behavior, however would accept it for v2.2 certification. Will be rejected for v2.3 certification.

        Attachments

          Expenses

            Activity

              Status Description

                People

                • Reporter:
                  BMeyer Benjamin Meyer
                • Votes:
                  0 Vote for this issue
                  Watchers:
                  0 Start watching this issue

                  Dates

                  • Created:
                    Updated:
                    Resolved: