Uploaded image for project: 'PROFINET IO-Device'
  1. PROFINET IO-Device
  2. PSPNS-1642

Submodule Plug while AR Startup not handled correctly

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Major
    • Resolution: Fixed
    • Affects Version/s: V3.5.26.0
    • Fix Version/s: V3.5.32.0
    • Component/s: Stack
    • Labels:
      None
    • Sprint:
      PI KW 6 2014
    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      According To Profinet Spec V2.3 Section 7.3.6.4 Submodule Plug Procedures between Connect Response and Application Ready shall not affect the current state but processed after application ready. That is, the
      submodule shall be still reported as 'No Submodule' in Prm End/Application Ready, even if application signaled a plug inbetween. After Application Ready the Stack should send the Plug Alarm with corresponding information.

        Attachments

          Expenses

            Activity

              Status Description

                People

                • Reporter:
                  BMeyer Benjamin Meyer
                • Votes:
                  0 Vote for this issue
                  Watchers:
                  0 Start watching this issue

                  Dates

                  • Created:
                    Updated:
                    Resolved: