Uploaded image for project: 'PROFINET IO-Device'
  1. PROFINET IO-Device
  2. PSPNS-1607

Inconsistent internal module configuration might occur if an AR is established while pulling a module is done at another AR

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Major
    • Resolution: Fixed
    • Affects Version/s: V3.5.28.0
    • Fix Version/s: V3.5.29.0
    • Component/s: Stack
    • Labels:
      None
    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      If a pull sequence is running for a module to one IO Controller using SystemRedundancy AR and now another IO Controller establishes another SystemRedundancy AR this might lead to inconsistent state in PLUGSM and PULLSM statemachines which may interrupt the running pull sequence.

        Attachments

          Issue Links

            Expenses

              Activity

                Status Description

                  People

                  • Reporter:
                    BMeyer Benjamin Meyer
                  • Votes:
                    0 Vote for this issue
                    Watchers:
                    0 Start watching this issue

                    Dates

                    • Created:
                      Updated:
                      Resolved: