if an invalid maxBridgeDelay value is configured by IO-Controller respond with an error

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V3.5.22.0
    • Fix Version/s: V3.5.29.0
    • Component/s: Stack
    • Labels:
      None
    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      Any value for the parameter maxBridgeDelay in PDIRGlobalData record is accepted without error in write record response. This might happen if a stack user updates from stack v3.4 to v3.5 without adapting his GSDML file accordingly or chooses a wrong DeviceAccessPoint in GSDML file. In this case an error shall be reported by the stack so that IRT is not possible (would not work anyway).