Uploaded image for project: 'PROFINET IO-Device'
  1. PROFINET IO-Device
  2. PSPNS-1510

Device handle not accepted in PNS_IF_ABORT_CONNECTION_REQ with 2 Backup ARs

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V3.5.19.0
    • Fix Version/s: V3.5.21.0
    • Component/s: Stack
    • Labels:
      None
    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      When 2 backup ARs are present, PNS_IF_ABORT_CONNECTION_REQ with hDeviceHandle = 2 is rejected with error TLR_E_PNS_IF_DEVICE_HANDLE_INVALID (0xC0300015).

      Same request is accepted with 1 backup AR or with 1 primary + 1 backup AR.

        Attachments

          Expenses

            Activity

              Status Description

                People

                • Reporter:
                  BMeyer Benjamin Meyer
                • Votes:
                  0 Vote for this issue
                  Watchers:
                  0 Start watching this issue

                  Dates

                  • Created:
                    Updated: