Uploaded image for project: 'PROFINET IO-Device'
  1. PROFINET IO-Device
  2. PSPNS-1491

Invalid Profinet Status Code in WriteRecord Response on PNS_IF_WRITE_RECORD_RSP with ulSta != TLR_S_OK

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V3.4.142.0
    • Fix Version/s: V3.4.144.0
    • Component/s: Stack
    • Labels:
      None
    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      If the users applications response on PNS_IF_WRITE_RECORD service contains ulSta != TLR_S_OK an invalid Profinet Status Code is reported on bus. (actually the first four bytes of write record data may be send back to the controller)

        Attachments

          Expenses

            Activity

              Status Description

                People

                • Reporter:
                  BMeyer Benjamin Meyer
                • Votes:
                  0 Vote for this issue
                  Watchers:
                  0 Start watching this issue

                  Dates

                  • Created:
                    Updated:
                    Resolved: