Uploaded image for project: 'PROFINET IO-Device'
  1. PROFINET IO-Device
  2. PSPNS-1389

sometimes no link on second fiber optic port after system reset

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Major
    • Resolution: Fixed
    • Affects Version/s: V3.4.138.3
    • Fix Version/s: V3.4.140.0
    • Component/s: COMX-CA-REFO Firmware
    • Labels:
      None
    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      After performing a System reset is might happen that it is not possible to establish a link at the second fiber optic port. The transceiver does not emit any light in such a case. Powercycling the Hardware is the only way to recover from this Situation.

        Attachments

          Expenses

            Activity

              Status Description

                People

                • Reporter:
                  BMeyer Benjamin Meyer
                • Votes:
                  0 Vote for this issue
                  Watchers:
                  0 Start watching this issue

                  Dates

                  • Created:
                    Updated:
                    Resolved: