Uploaded image for project: 'PROFINET IO-Device'
  1. PROFINET IO-Device
  2. PSPNS-1381

[cifX 104-RE]: when using Sycon.net database on CIFX 104-RE setting the IP address via bus leads to corrupt file system

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Major
    • Resolution: Fixed
    • Affects Version/s: V3.4.36.1
    • Fix Version/s: V3.4.40.0
    • Component/s: CIFX 50-RE Firmware
    • Labels:
      None
    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      if CIFX 104-RE is used (which is ISA, not PCI!) with regular cifX firmware and sycon.net database setting the IP Address via leads to a situation that firmware is no longer bootable after power cycle

        Attachments

          Issue Links

            Expenses

              Activity

                Status Description

                  People

                  • Reporter:
                    BMeyer Benjamin Meyer
                  • Votes:
                    0 Vote for this issue
                    Watchers:
                    0 Start watching this issue

                    Dates

                    • Created:
                      Updated:
                      Resolved: