SNMP counter of "outdiscard" frames increases if port has no link and multicast frames are received on the other port

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V3.4.138.3
    • Fix Version/s: V3.4.138.4
    • Component/s: Stack
    • Labels:
      None
    • Account:
      SPC Profinet Slave V5 operational (SPCPROFINE)

      Description

      the error counter "outdiscard" that can be read by SNMP (which is done by e.g. Siemens Step7) increases for a port whose link is down.
      This is unexpected since no other Profinet device with this behavior is known