in case ALPMI generates an ErrorIndication CMDEV aborts the AR (as requested by specification) but uses an incorrect error code

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V3.4.36.1
    • Fix Version/s: V3.4.37.0
    • Component/s: Stack
    • Labels:
      None
    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      if the ALPMI statemachine detects an error it reports this to CMDEV.
      CMDEV shall abort the AR. This is done. However CMDEV ignores the error code provides by ALPMI and uses a hardcoded error code instead.
      This hard coded error code is 0xCF81FD00 which is reserved according to specification.