Uploaded image for project: 'PROFINET IO-Device'
  1. PROFINET IO-Device
  2. PSPNS-1220

RCX_SET_FW_PARAMETER_REQ does not work if length of NameOfStation is a multiple of 4

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Major
    • Resolution: Fixed
    • Affects Version/s: V3.4.36.0
    • Fix Version/s: V3.4.36.1
    • Component/s: CIFX 50-RE Firmware
    • Labels:
      None
    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      RCX_SET_FW_PARAMETER_REQ delivers error 0xC0000007 when using correct parameter length (if parameter length is a multiple of 4).
      The command is only accepted if parameter length is 4 bytes longer than the real data´length.

      parameter length of e.g. 7 is working fine.

        Attachments

          Expenses

            Activity

              Status Description

                People

                • Reporter:
                  BMeyer Benjamin Meyer
                • Votes:
                  0 Vote for this issue
                  Watchers:
                  0 Start watching this issue

                  Dates

                  • Created:
                    Updated:
                    Resolved: