performing SNMP walk does not deliver all connected neighbors in LLDP Remote MIB

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V3.4.35.0
    • Fix Version/s: V3.4.36.1
    • Component/s: Stack
    • Labels:
      None
    • Account:
      SPC Profinet Slave (SPCPROFINE)

      Description

      when IO-Device is connected to one neighbor on each Ethernet Port the LLDP Remote MIB should contain one entry per port.

      however performing an SNMP walk only delivers one of the neighbors.

        Attachments

          Expenses

            Activity

              Status Description

                People

                • Reporter:
                  BMeyer Benjamin Meyer
                • Votes:
                  0 Vote for this issue
                  Watchers:
                  0 Start watching this issue

                  Dates

                  • Created:
                    Updated: