Disabled AR is unexpectedly established after switching the bus state to ON

    Details

    • Account:
      SPC Profinet Master V3 operational (SPCPROFINETMA)

      Description

      The stack provides the possibility to control the status of the individual ARs using PNM_AP_CMD_CHANGE_ARSTATE_REQ.

      For example, the application can switch off the individual ARs at runtime using the ‘PNM_AP_ARSTATE_REQ_SHUTDOWN’ status. However, if the bus status is then switched to ON, either explicitly through the DPM service or implicitly through the status ‘PNM_AP_ARSTATE_REQ_SHUTDOWN’ for handle 0 (IO controller), all ARs are established, including those previously deactivated.

        Attachments

          Issue Links

            Expenses

              Activity

                Status Description

                  People

                  • Reporter:
                    RAamidi Redouane Aamidi
                  • Votes:
                    0 Vote for this issue
                    Watchers:
                    0 Start watching this issue

                    Dates

                    • Created:
                      Updated:
                      Resolved: