Generate and use dedicated error code in case configuration exceeds the available memory for AR configuration parameters

    Details

    • Type: Change
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: None
    • Fix Version/s: V3.5.0.10, V3.5.1.0
    • Labels:
      None
    • Account:
      SPC Profinet Master (SPCPROFINETMA)

      Description

      The firmware reserves a specific amount of memory for usage of configuration parameters. In case the configuration contains more parameter data than buffer capacity, this is currently rejected with error "HIL_OUT_OF_MEMORY" 0xC0000003.

      In case application sends the packets individually, this may be sufficient. However, in case of offline database configuration, it is hard to find out, why the configuration failed.

      A new error code ERR_PNM_AP_CFG_RECORD_STORAGE_FULL is introduced to explicitly indicate this situation of "too much record data".