Uploaded image for project: 'PROFINET IO-Controller V3'
  1. PROFINET IO-Controller V3
  2. PSPNMV3-542

Unexpected timeout error when using Get Device Info service

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: V3.1.0.0, V3.2.0.0, V3.3.0.0
    • Fix Version/s: V3.3.0.8, V3.3.1.0
    • Labels:
      None
    • Account:
      SPC Profinet Master V3 operational (SPCPROFINETMA)

      Description

      When using the Get Device Info service after issuing a Bus Scan service, the Get Device Info service response might contain an unexpected timeout error. The problem occurs when the scanned profinet device does not respond within 20 ms to a DCP Identify All with DelayResponseFactor == 1.

      According to Specification a DelayResponseFactor==1 remands a timeout of 400ms on the sender side.

        Attachments

          Issue Links

            Expenses

              Activity

              There are no comments yet on this issue.

                People

                • Reporter:
                  AMesser Andreas Messer
                • Votes:
                  0 Vote for this issue
                  Watchers:
                  0 Start watching this issue

                  Dates

                  • Created:
                    Updated:
                    Resolved: