Invalid packet length for Get IOD Configuration service confirmation

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: None
    • Fix Version/s: V3.3.0.1, V3.3.1.0
    • Labels:
      None
    • Account:
      SPC Profinet Master (SPCPROFINETMA)

      Description

      The Get IOD configuration service confirmation packet has an invalid packet length value "306" with structure version 1. It is expected that the length is 296 with this structure version.

        Attachments

          Expenses

            Activity

              Status Description

                People

                • Reporter:
                  ATilatti ATilatti (Inactive)
                • Votes:
                  0 Vote for this issue
                  Watchers:
                  0 Start watching this issue

                  Dates

                  • Created:
                    Updated: